Quality · Process yield
First-pass and rolled yield calculator
Enter first-pass counts for up to three serial steps. The calculator separates each step's FPY from final-good yield.
- Runs in your browser — no data sent
- Count-based yield convention
- English · 한국어
Step counts and flow assumptions
Yield estimates
Enter at least one complete process step to calculate yield.
Formula, assumptions, and example
Definitions
For each step, FPY = units passing that step on the first attempt ÷ units entering that step. Exclude units scrapped, rerun, retested, returned, or diverted to offline repair from first-pass-good counts. This is the unit-count FPY convention described by the ASQ glossary (see references).
Rolled first-pass yield estimate = the product of the entered step FPYs. It is a count-based serial-process estimate. ASQ distinguishes unit-based total process yield from defect-based Poisson RTY. This page names its calculation method. It treats the models as different.
Worked example
Step FPYs are 98/100 = 0.98, 95/100 = 0.95, and 99/100 = 0.99. Their product is 0.98 × 0.95 × 0.99 = 0.92169, or 92.169% (92.17% displayed). The three 100-unit denominators illustrate rate arithmetic; they do not reconcile a pass-only cohort across steps. Only under a separately confirmed common-population model would 92.169 be a modeled expected no-rework count, not an observed whole-unit count.
Flow and final yield
Comparable serial routing is needed to interpret the product as a rolled estimate. Multiplying marginal rates does not by itself prove the observed fraction of a single cohort that passed every step; it assumes suitable common-population/representativeness conditions. Different row counts can indicate unrelated batches, split/merge routing, or rework loops.
Final-good yield is shown only when the entered final-good count is explicitly confirmed as the same initial cohort after completed routing with no outside additions. It is final good ÷ initial input and can include successful rework; it is not RTY. A missing or unconfirmed final count is suppressed.
Scope
The modeled no-rework count is initial input × product of step FPYs and appears only after confirming a comparable common flow. It is an expected model value and may be fractional. This calculator does not model parallel branches, split/merge routing, loops, or capability; see the ASQ references for the source definitions and model distinction.
References · checked 2026-10-11
- ASQ Quality Glossary — First Pass Yield — Defines first-pass yield and excludes scrap, rerun, retest, return, or offline repair from units passing without rework. Checked 2026-10-11.
- ASQ — Rolled Throughput Yield and Total Process Yield — Accessible abstract discusses product of sequential yields and distinguishes Poisson defect-based RTY from binomial unit-based TPY. Checked 2026-10-11; full text was not accessed.